V90 PVC INSULATED





Application:
Marine Trailer
Conductor:
Tinned Copper Wire (TCW) to AS1125
Insulation:
RoHS Compliant 90°C PVC to AS3808
Core Colours: 3 Core: White, Yellow, Brown
5 Core: White, Yellow, Brown, Red, Green
7 Core: White, Yellow, Brown, Red, Green, Blue, Black
Sheath Colour:
White
Packs:
30, 100, 1000 metres, bulk drum - depending on product type

Code Nominal
Area
(mm²)
Insulation
Thickness
(mm)
Sheath
Thickness
(mm)
*AMP
Rating
JASO D609
at 30°C
Electrical
Resistance
at 20°C
(ohm/km)
Nominal
O.D.
(mm)
Mass
(kg/100m)
MTS32603 3 x 1.84 0.4 0.6 19 10.1 7.2 8.4
MTT51602 5 x 0.5 0.4 0.6 6 40.1 5.4 4.9
MTT53202 5 x 1.0 0.4 0.6 8 20 7.2 8.2
MTT73202 7 x 1.0 0.4 0.6 7 20 7.8 10.9

* AMP RATING: TO JASO D609 derating factors apply

Derating Factors for Ambient Temperatures °C
Temperature
30
40
50
60
70
Factor
1.00
0.90
0.76
0.60
0.45