Tel: (03) 8791 0300 | Fax: (03) 9794 0031 | Email: enquiries@tycab.com.au | Web: www.tycab.com.au

  • Home
  • Latest News
  • About Tycab
  • Tycab Products
  • Contact Us
  • Login

BROCHURE Download

DOWNLOAD
TYCAB MARINE BROCHURE

marine.jpg


Flat Twin Sheath Battery


PrintE-mail

TINNED COPPER WIRE (TCW) TO AS/NZS 1125





Applications:
Battery Winches, Feeds, Charges, Power & Solar Generators
Conductor:
Tinned Copper Wire (TCW) to AS/NZS 1125
Insulation:
RoHS Compliant 5V90 P.V.C. to AS/NZS 3808
Core Colours:
Red & Black
Sheath: RoHS Compliant 5V90 P.V.C. to AS/NZS 3808
Sheath Colours:
Black
Packs:
30 metres - other packs by request
Code NEAREST
B&S
Nominal
Area
(mm²)
Insulation
Thickness
(mm)
Sheath
Thickness
(mm)
*AMP
Rating
JASO D609
at 30°C
Electrical
Resistance
at 20°C
(ohm/km)
Nominal
O.D.
(mm)
Mass
(kg/100m)
STOCK
ITEM
MWS296032 8 7.7 0.9 0.8 59 2.43 7.1 x 12.5 22
MWS2168032 6 13.5 1.1 0.8 82 1.42 8.8 x 16.0 36.0
MWS2399032 2 32.0 1.7 0.96 150 0.61 13.0 x 24.0 83.0

* AMP RATING: TO JASO D609 derating factors apply

Derating Factors for Bundling of Single Core Cables
No of Cables
1
2
3
4
5
6 to 7
8 to 10
11 to 12
Factor
1
0.8
0.7
0.6
0.55
0.5
0.45
0.4



Derating Factors for Ambient Temperatures °C
Temperature
30
40
50
60
70
Factor
1.00
0.90
0.76
0.60
0.45


Figure 8 Parallel Webbed
Tycab Australia Pty Ltd: 269 Frankston - Dandenong Rd, Dandenong VIC 3175 ABN: 43 100 305 833 ACN: 100 305 833