| Application: |
General Purpose Automotive Wiring |
| Conductor: |
OXYGEN FREE Plain Copper Wire to AS1125 |
| Insulation: |
V90 PVC Insulated to AS3808 |
| Colours: |
Red, Blue, Green, White, Black, Brown, Violet, Orange, Grey and the widest range trace colours |
| Packs: |
30, 50, 100, 500, 1000 metres, bulk drum - depending on product type |
| Code | * MM Industry Equiv. |
NZ Equiv. |
Strand No. / Size |
Nominal Area (mm²) |
**AMP Rating at 30°C |
Insulation Thickness (mm) |
Electrical Resistance at 20°C (ohm/km) |
Nominal O.D. (mm) |
Mass (kg/100m) |
|
|---|---|---|---|---|---|---|---|---|---|---|
* MM is an industry term that identifies cable size and is not CONDUCTOR CROSS SECTION AREA
** AMP RATING: TO JASO D609 derating factors apply
| Derating Factors for Bundling of Single Core Cables | ||||||||
| No of Cables |
1
|
2
|
3
|
4
|
5
|
6 to 7
|
8 to 10
|
11 to 12
|
| Factor |
1
|
0.8
|
0.7
|
0.6
|
0.55
|
0.5
|
0.45
|
0.4
|
| Derating Factors for Ambient Temperatures °C | |||||
| Temperature |
30
|
40
|
50
|
60
|
70
|
| Factor |
1.00
|
0.90
|
0.76
|
0.60
|
0.45
|